2014/01/23
FW : sas3xfw140123.fw
	Revision: 03.01.00.09  01/23/14
	command "fdl code" to update

	Initial release.

MFG data : Mfg12g140109.dat
	command "fdl mfgb" to update
	
	Initial release.

2014/02/06
FW : sas3xfw140205.fw
	Revision: 03.01.01.09  02/05/14
	command "fdl code" to update

	1, modify some system information printed text.

MFG data : Mfg12g1400205.dat
	command "fdl mfgb" to update
	
	1, Change ARC8028-16, ARC8028-12 SGPIO setting.
		device-id 	Rev.
		0x33 				02 
		0x34 				02
		
2014/02/11
FW : sas3xfw140211.fw
	Revision: 03.01.02.09  02/11/14
	command "fdl code" to update

	1, Fix cli command "dhpm" reject valid slot index.
	2, Fix wrong connector attribute mesage shown.

2014/03/07
FW : sas3xfw1400307.fw
	Revision: 03.01.03.0A  03/07/14
	command "fdl code" to update

	1, Support ARC8028 Dual function.
	2, Fix ARC8028 Auto-Fan control.

MFG data : Mfg12g140307.dat
	command "fdl mfgb" to update

	1, Support ARC1883IX 12/16/24 bays, Pre-Released
		ID 0x1C, rev 0x00
		ID 0x1D, rev 0x00
		ID 0x1D, rev 0x00
	2, Update LED SGPIO stream sequence.
		ID 0x0E, rev 0x02
		ID 0x0F, rev 0x02
	3, Support customer model, Pre-Released
		ID 0x02, rev 0x00
		ID 0x05, rev 0x00
		ID 0x06, rev 0x00
		ID 0x09, rev 0x00
		ID 0x40, rev 0x00

2014/03/21
FW : sas3xfw1400321.fw
	Revision: 03.01.04.0B  03/21/14
	command "fdl code" to update

	1,Fix cli command "link" set wrong 6G/3G link rate.
	2,Fix LCM show wrong voltage text.
	3,Dsiable the LCM task, if not plug a LCM during POST.

2014/03/28
FW : sas3xfw1400326.fw
	Revision: 03.01.05.0D  03/26/14
	command "fdl code" to update

	1, Adjust the chip terperature.
	2, Support ARC8018 reduadant function.
	3, Support Set DHPM mode function for VM.exe(v1.48)
	
MFG data : Mfg12g140328.dat
	command "fdl mfgb" to update
	
	1, Adjust the Chip default High-Warning temperature to 90'C.
	2, Adjust the slot start index number,
			otherwsie LSI HBA BIOS won't recognize drive correctly.
		ID 0x0F, rev. 0x04	ID 0x0E, rev. 0x04	ID 0x3C, rev. 0x03
		ID 0x39, rev. 0x03	ID 0x34, rev. 0x04	ID 0x33, rev. 0x04
		ID 0x35, rev. 0x03	ID 0x1C, rev. 0x02	ID 0x1D, rev. 0x02
		ID 0x1E, rev. 0x02	ID 0x09, rev. 0x02	ID 0x02, rev. 0x02
		ID 0x05, rev. 0x02	ID 0x06, rev. 0x02	ID 0x40, rev. 0x02

2014/04/03
FW : sas3xfw140403.fw
	Revision: 03.01.06.0E  04/03/14
	command "fdl code" to update

	1, Fix the "con" command always show 3 external ports.
	2, Fix ARC8018 can't switch I2C control.

2014/04/09
FW : sas3xfw140409.fw
	Revision: 03.01.07.0F  04/09/14
	command "fdl code" to update

	1, Fix get wrong FW size to Sync. FW when Master expander FW region 1 is empty.
	2, The 1.5G link rate is for emulation, not for normal operation. remove the 1.5G option.
	3, Fix the error for link rate setting.

2014/04/23
FW : sas3xfw1400423.fw
	Revision: 03.01.08.0F  04/23/14
	command "fdl code" to update

	1, Fix when backup expander send log information to master and also destory the received data.
	
MFG data : Mfg12g140423.dat
	command "fdl mfgb" to update
	
	1, Support new model ARC-8008 series,
		ID 0xBC, ID 0xBF, ID 0xBE, ID 0xB9, ID 0x89, 
		ID 0x82, ID 0x85, ID 0x86, ID 0xC0,
	
	2, Adjust slot information to report correct SMP response data for LSI HBA internal use.
		ID 0x35 rev. 0x04, ID 0x33 rev. 0x05, ID 0x34 rev. 0x05
  	ID 0x39 rev. 0x04, ID 0xB9 rev. 0x01, ID 0x3C rev. 0x04,
 		ID 0x0F rev. 0x05, ID 0x0E rev. 0x05, ID 0x1C rev. 0x03,
  	ID 0x1D rev. 0x03, ID 0x1E rev. 0x03, ID 0xBC rev. 0x01,
  	ID 0x8F rev. 0x01, ID 0x8E rev. 0x01, ID 0x09 rev. 0x03,
  	ID 0x02 rev. 0x03, ID 0x05 rev. 0x03, ID 0x06 rev. 0x03,
  	ID 0x40	rev. 0x03, ID 0x89 rev. 0x01, ID 0x82 rev. 0x01,
  	ID 0x85 rev. 0x01, ID 0x86 rev. 0x01, ID 0xC0	rev. 0x01,
  	
2014/05/15
FW : sas3xfw1400515.fw
	Revision: 03.01.09.10  05/15/14
	command "fdl code" to update

	1, Add a delay before initialize the LCM.
	2, Fix Areca LCM access LED not work.
	
MFG data : Mfg12g140515.dat
	command "fdl mfgb" to update
	
	1, Fix wrong temperature element number.
		ID 0x0E rev. 0x07
		
	2, For 12/16 bays expander device, adjust SGPIO bits stream to fit for X28 chip.
  	ID 0x0F rev. 0x06, ID 0x0E rev. 0x07, ID 0x39 rev. 0x05, ID 0xB9 rev. 0x02, 
  	ID 0x8F rev. 0x01, ID 0x8E rev. 0x02, ID 0x1D rev. 0x04, ID 0x1E rev. 0x04,
  	ID 0x02 rev. 0x04, ID 0x05 rev. 0x04, ID 0x06 rev. 0x04, ID 0x40 rev. 0x04,
		ID 0x82 rev. 0x02, ID 0x85 rev. 0x01, ID 0x86 rev. 0x02, ID 0xC0 rev. 0x01,
	
2014/08/13
FW : sas3xfw140813.fw
	Revision: 03.01.10.15  08/13/14
	command "fdl code" to update

	1, Update DHPM conflict with spinup control issue.
	2, Support sensor W83785.
	3, Tune the ARC-8028 fan speed PWM value.
	4, Support new model ARC-8028 32 bays.
	5, Fix spinup control function.
	6, Fix Auto Fan ThermalFanZone as ARC-8016 series
			<15, 25, 30, 35, 40, 45, >50'C
	7, Limit the ARC-8028 PCB-A, ARC-8018 PCB-B series to 6G link speed.
	
MFG data : Mfg12g140807.dat
	command "fdl mfgb" to update

	1, Fix wrong subtractive PHYs setting
		 ID 0x1C rev. 0x04, ID 0x1E rev. 0x05, ID 0x1E rev. 0x05
	2, Support new model ARC8088
		 ID 0xC3rev. 0x01, ID 0xC4 rev. 0x01, ID 0xC5 rev. 0x01


2014/09/04
FW : sas3xfw140904.fw
	Revision: 03.01.11.18  09/04/14
	command "fdl code" to update

	1, Support the power module disabled when fan fail.
	2, set dhpm default ON as default.
	3, CLI "st default" to reset all the value as default.
	
MFG data : Mfg12g140904.dat
	command "fdl mfgb" to update

	1, Volt1 sensor input is 0.95V not 0.9V
		 ID 0x33 rev. 0x06, ID 0x34 rev. 0x06, ID 0x35 rev. 0x05
		 ID 0x39 rev. 0x08, ID 0x47 rev. 0x03, ID 0x0F rev. 0x07
		 ID 0x0E rev. 0x08, ID 0x3C rev. 0x05, ID 0x05 rev. 0x05
		 ID 0x09 rev. 0x04, ID 0x02 rev. 0x05, ID 0x40 rev. 0x05
		 ID 0x06 rev. 0x05,

2014/10/16
FW : sas3xfw141016.fw
	Revision: 03.01.02.1B  10/16/14
	command "fdl code" to update

	1, Support device ID 0x3, 0x7
	2, Support set all slots with same link speed rate
	   cli command "link 255 High-Rate(D) Low-Rate(D)"
	3, Enable the user can set the ARC-8028 PCB-A, ARC-8018 PCB-B series expander link speed to 12G,
		 But default is 6G limit.
	4, support cli command "edfb", which is same function as "dhpm"
	5, Add EDFB and LINKRATE functions for VM.exe (Version great than V1.51)
	6, Fix device ID 0x39 LCM issue.
	7, Support turn the power module off when any one power fans failed.
		 (Only some devices H/W can support)
	
MFG data : Mfg12g141006.dat
	command "fdl mfgb" to update

	1, Support device ID 0x3, 0x7, 0x42, 0x38
		 ID 0x03 rev. 0x01, ID 0x07 rev. 0x01,
		 ID 0x42 rev. 0x00, ID 0x38 rev. 0x00,

2014/10/24 	Released
FW : sas3xfw141024.fw
	Revision: 03.01.13.1D  10/24/14
	command "fdl code" to update

	1, Fixed for missing reduadant auto-reset code.
	2, Fixed "st default" did not reset the temperature element threshold values to default.
	3, Changed the methodlogy for redundant setup-data comparison.
	4, Fixed the issue for host link lost unexpectedly.

MFG data : Mfg12g141023.dat
	command "fdl mfgb" to update
	
	1, Update device ID 0x42, 0x38
		 ID 0x42 rev. 0x01, ID 0x38 rev. 0x01


2014/12/03	Released	
FW : sas3xfw141203.fw
	Revision: 03.01.14.22  12/03/14
	command "fdl code" to update
	
	1)Support the rate option of link command can use string 12g/6g/3g as arguments.
	2)Fix link status for the cable that not connect any device but get a link rate.
	3)Support ARC8018 PCB V1.0.
	4)Support 64 bays Device.
	5)Support ARC8088 PCB-B.
	6)Fix a issue that hang at POST when new device ID support.

MFG data : Mfg12g141128.dat
	command "fdl mfgb" to update

	1)Support ARC8018 PCB V1.0,
		ID 0x0E rev. 0x10
		ID 0x0F rev. 0x10
	2)Support Arc8088-12/16/24 bays,
		ID 0xC3 rev. 0x03
		ID 0xC4 rev. 0x03
		ID 0xC6 rev. 0x01 
	3)support 64 bays,
		ID 0x3D rev. 0x01
		ID 0x3E rev. 0x01
	4)Support ARC8018 12 bays,
	  ID 0x3A rev. 0x00
	5)support ARC8018 24 bays,
	 	ID 0x48 rev. 0x01
	 	ID 0xC8 rev. 0x00
	6)Fixed Device ID 0x38, 0x42 external cable extend attribute,
		ID 0x42 rev. 0x01
		ID 0x38 rev. 0x01


2014/12/18	Released	
FW : sas3xfw141218.fw
	Revision: 03.01.15.25  12/18/14
	command "fdl code" to update

	1)Fix the 64/42 bays device fan speed.
	2)Fix the 64 bays device can't get enclosure temperature.
	3)Fix 64 bays ID 0x42, 0x3D, 0x3E DHPM default setting.
	4)Fix 64 bays LCM show wrong FW & version.
	5)ARC8010/8028 PCB ver. 1.0 default 12G, PCB ver. B default 6G.
	6)Fix ARC12/24 power off pin different ARC16 H/W.


MFG data : Mfg12g141209.dat
	command "fdl mfgb" to update

	1)Support ARC8018 ID 0x42 PCB V1.0
		ID 0x42 rev. 0x11
	2)UPdate ID 0x3D, 0x3E PWM value and Phy28-35 enabled
		ID 0x3D rev. 0x03
		ID 0x3E rev. 0x03
		

2015/02/25	Released
FW : sas3xfw150225.fw
  Revision: 03.01.16.28  02/25/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
  
	1)Remove the "optic" option for "cable" command,
	  support optical cable automatically.
	2)Support new ARC8028 PCB V1.0
	3)Fix the the driven strength setting when use SDK3 kernel.	
	4)Fix ARC1883IX expander set wrong external connector and make FW hang.
	5)Under Dual-JOBD reduadant environment and expander boot later than HBA
		the HBA will get wrong SMP information at initial sync. stage.


MFG data : Mfg12g150225.dat
	command "fdl mfgb" to update
	
	1)Support new ARC8028 PCB V1.0
		ID 0x34 Rev. 0x10
		ID 0x33	Rev. 0x10
		ID 0x35	Rev. 0x10
	2)Under Dual-JOBD reduadant environment and expander boot later than HBA
		the HBA will get wrong SMP information at initial sync. stage.
		
		ID			Revision		New PCB
		-----------------------------------
		35			Rev. 0x06		
	  34			Rev. 0x07
	  33			Rev. 0x07
		33  		Rev. 0x11		Y
		34			Rev. 0x11		Y
		35			Rev. 0x11		Y
		47			Rev. 0x04
		0E			Rev. 0x09
		0F			Rev. 0x08
		3C			Rev. 0x06
		0E			Rev. 0x11		Y
		0F			Rev. 0x11		Y
		39  		Rev. 0x09
		3A  		Rev. 0x01
		3F  		Rev. 0x01
		42  		Rev. 0x03
		42  		Rev. 0x12		Y
		38  		Rev. 0x03
		05			Rev. 0x06
		06			Rev. 0x06
		40			Rev. 0x06
		03			Rev. 0x06
		09			Rev. 0x05
		48			Rev. 0x02
		07			Rev. 0x02
		03			Rev. 0x02
	
	2)Support PCB V1.0 for ID 0x39
		39			Rev. 0x10		(New PCB)
	3)ARC8008 PCB ver. B -> ver. C
		8E			Rev. 0x10
		8F			Rev. 0x10
		BC			Rev. 0x10
	4)Disable the beep for master expander sensor data transfer retry.


2015/03/12	Released
FW : sas3xfw150312.fw
Revision: 03.01.17.29  03/12/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update

	1)ARC-8028 external port are not enabled when set as single controller.
	
MFG data : Mfg12g150312.dat
	command "fdl mfgb" to update

	1)Support PCB V1.0 for ID 0x3F
		3F			Rev. 0x10		(New PCB)
	2)Fix the ID 0x47 data(Rev. 0x04 did) not fix the previous Dual-JOBD issue.
		47			Rev. 0x05


2015/05/20	Released
FW : sas3xfw150520.fw
Revision: 03.01.18.2E  05/20/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update

	1)Fix fan speed up-down change too fast when auto fan speed support.
	2)Rewrite the Shutdown power module methodlogy, 
		when all fans in the power modules are failed, shutdown this power module.
	3)Fix ARC8028-12/16/25(PCB V1.0), some Fans RPM reading error.	
	4)Fix ID 0x3F,
			Fan sensor reading error and shownn string,
			LCM sometimes shown wrong string at POST stage,
			SES report Temperature unknown error.
	5)Fix DHPM user setting default value for PCB V1.0.

MFG data : Mfg12g150520.dat
	command "fdl mfgb" to update

	1)Support ARC8018 PCB V1.0
		3C			Rev. 0x10
		3F			Rev. 0x11
		39			Rev. 0x11
		3A			Rev. 0x10
		06			Rev. 0x10
		48			Rev. 0x10
		09			Rev. 0x10
	2)Support ARC8038 ID 0x36 
		39			Rev. 0x00
	3)Fix fan PWM value for ARC8028 PCB V.10
		33			Rev. 0x12
		34			Rev. 0x12
		35			Rev. 0x12



2015/07/01	Released
FW : sas3xfw150701.fw
Revision: 03.01.19.31  07/01/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
  
	1)Support ARC4038.
	2)Support LCD Esc key to Mute beep.
	3)Support inquiry VPD 0x83H.
	4)Support ID 0x49.
	5)For ARC8028 PCB v1.0, support to change the fan PWM value.
	6)Adjusd ARC8028-12/16/24 PCB v1.0 fan rpm value.


MFG data : Mfg12g150701.dat
	command "fdl mfgb" to update

	1)Support ARC4038.
		36			Rev. 0x02
	2)Fix ID 0xBC PCB C. slot to phy mapping
		BC			Rev. 0x11
	3)Fix ID 0x3F Slot-PHY mapping.
		3F			Rev. 0x12
	4)Add ID 0x49 same as 0x3F but use ARC8000 backplane.
		49			Rev. 0x10
	5)Fix ARC8018-12 ID 0xE connector attribute.
		0E			Rev. 0x12
	6)Fix ID 0x07 wrong Fan02 register value.
		07			Rev. 0x03
	7)Fix ID 0x09 number of temperature elements
		09			Rev. 0x11


2015/07/20 Released
FW : sas3xfw150717.fw
Revision: 03.01.20.33  07/17/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
  
	1)Fix VPD 0x83 return value.
	2)Device ID 0x49 set LCM-support as deflaut.
	3)Fix CLI "sub" command bug.
	4)Support ARC8018 device ID 0x4A 24 bays.


MFG data : Mfg12g150716.dat
	command "fdl mfgb" to update
	
	1)Support ARC8008 PCB Ver. C 24 bays for ID 0x89, 0xC8, 0xC9,
		89			Rev. 0x10			,4U
		C8			Rev. 0x10			,2U
		C9			Rev. 0x10			,2U
	2)Support ARC8008 PCB Ver. C 16 bays for ID 0x82
		82			Rev. 0x10
	3)Support ARC8008 PCB Ver. C 12 bays for ID 0x86
		86			Rev. 0x10
	4)Fix ID 0x49, slot ElementIndex for Phy 1
		49			Rev. 0x11
	5)Support ARC8018 device ID 0x4A 24 bays
		4A			Rev. 0x10
	6)Support Controller device ID 0xCA 24 bays with ARC8000 backplane
		CA			Rev. 0x10
	7)Fix ARC4038 PHY12-15, PHY24-27 attribute
		36			Rev. 0x03


2015/08/11 Beta
MFG data : Mfg12g150811B2.dat
	command "fdl mfgb" to update
	
	1)Support ARC8008 PCB Ver. C 12 bays for ID 0xBA,
		BA			Rev. 0x10

2015/08/27 Beta
FW : sas3xfw150827B0.fw
Revision: 03.B0.00.36  08/27/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
  
	
2015/09/24 Released 
FW : sas3xfw150924.fw
  Revision: 03.01.21.38  09/24/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
  
	1)Support SAS downgrade mode when host request.
	2)Fix PSU(ARC430) yellow( Fail) LED not work.
	3)Support ARC8018/ARC8008 + ARC8006 6G backplane.
	4)rewrite ARC4038 PowerDownbyLink function.
	5)Support ARC8018 with x48 chip.

MFG data : Mfg12g150924.dat
	command "fdl mfgb" to update
	
	1)Support ARC8008 PCB Ver. C, 12 bays for ID 0xBA,
		BA			Rev. 0x10
	2)Support ARC8018 PCB Ver. >= 1.0  for ARC8006 backplane, 12 bays, 
		4F			Rev. 0x10
	3)Support ARC8018 PCB Ver. >= 1.0  for ARC8006 backplane, 16 bays,
		50			Rev. 0x10
	4)Support ARC8008 PCB Ver. C, 16 bays for ID 0xB9,
		B9			Rev. 0x10
	5)Support ARC8018 24 bays, x36,
		4C			Rev. 0x00
	6)Support ARC8018 24 bays, x48,
		4D			Rev. 0x00
	7)Support ARC8018 24 bays, x48,
		4E			Rev. 0x00
	8)Fix ARC4038 model name.
		36			Rev. 0x04
	9)Support ARC8008 PCB Ver. >= 1.0  for ARC8006 backplane, 12 bays, 
		CF			Rev. 0x10
 10)Support ARC8008 PCB Ver. >= 1.0  for ARC8006 backplane, 16 bays,
		D0			Rev. 0x10 


2015/09/30 Released 
FW : sas3xfw150924.fw
  Revision: 03.01.22.39  09/30/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
  
	1)For the expander models that support ARC8000 backplane only, we set the external ports
	  max. link speed to 6G as default.

2015/10/22 Released 
FW : sas3xfw151022.fw
  Revision: 03.01.23.3B  10/22/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update


	1)Fix PSU3 detection error on 4U expander.
	2)For some model backplanes, when slave expander take control,
	  it need more delay before issue I2C request.
	3)Fix when SAS HAB connects the Mini-SAS 4X connector(6G) of ARC4038,
	  it will failed on slot led identification.
 	4)Set the Enclosure Warning temperature to 70'C as default.
		make same as SAS controller.


MFG data : Mfg12g151014.dat
	command "fdl mfgb" to update
	
	1)Fix the Mini-SAS 4X connector type value of ARC4038.
	2)Fix some models of ARC8008 controller (PCB version >= 1.0) external port led not work correctly.
		8F			Rev. 0x11
		8E			Rev. 0x11
		BA			Rev. 0x11
		B9			Rev. 0x11
		82			Rev. 0x11
		86			Rev. 0x11

2015/12/11 Released 
FW : sas3xfw151211.fw
  Revision: 03.01.24.3F  12/11/15
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update


	1)Fix SES temperature Threshold out function.
	2)Fix when SES temperature OVT disappear and read the status immediately,
		will still return critical condition.
	3)Rewrite SES Cooling element critical condition detection code.

MFG data : Mfg12g151014.dat
	command "fdl mfgb" to update
	
	1)Fix device ID 0x4C and 0x4E only support 2 PSU modules.
		4C			Rev. 0x11
		4E			Rev. 0x11



2016/04/13 Release
FW : sas3xfw160413.fw
  Revision: 03.01.25.4D  13/04/16
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
	
	1)Support new model ARC-8008 24 bays 4U controller,
		CC			Rev. 0x10
  2)Support ARC8018 12 bays device,
  	52 			Rev. 0x10
  3)Support ARC8008 64 bays device,
  	D3 			Rev. 0x10
  4)For Avago 12G HBA FW restriction, update fw to make external port support end device.
  5)Fix phy-slot mapping for external port.
  6)Support new model ARC-8008 24 bays 2U controller,
  	BF 			Rev. 0x10
	7)Support new model ARC-8008 64 bays 4U controller,
		C2 			Rev. 0x10
		
	

MFG data : Mfg12g160413.dat, Mfg12gN160413.dat
	command "fdl mfgb" to update
	
	1)Support new model ARC-8018 16 bays 2U chasis with 6G link speed
		51			Rev. 0x10
	2)Support new model ARC-8018 12 bays 2U chasis with 6G link speed
		52 			Rev. 0x10
	3)Fix ARC8018 24 bays ID 0x09 PHY24-27 PHY32-35connector type error.
	  0x09		Rev. 0x12
	4)Support new model ARC-8008 64 bays 4U chasis with 6G link speed
		D3 			Rev. 0x10
	5)Update ARC-8008 64 bays 4U chasis ID 0xD3 external connector LED issue.
		D3 			Rev. 0x11
	6)Fix ARC8028 32 bays ID 0x47 PHY12-19 connector type error.
		47			Rev. 0x06	
	7)Support new model ARC-8008 24 bays 2U controller ID 0xBF
		BF 			Rev. 0x10
	8)Support new model ARC-8008 64 bays 4U controller ID 0xC2
		C2 			Rev. 0x10
	9)Support new model ARC-8008 15 bays 2U controller ID 0xCB
		CB 			Rev. 0x10

	Note,
	For the sake that MFG data file take too long time to download and
	some models that are mature and not need to updated
	(all of them are models with PCB rev. less than 1.0)
	So we rebuild a new MFG file that remove these models data too reduce the download time.
	The alternative MFG file will name as "Mfg12gNYYMMDD.dat"


2016/05/16 Release
FW : sas3xfw160413.fw
  Revision: 03.01.26.50  16/05/16
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
	
	1)Fix for ARC8008 controller GAL status issue that make some CLI commands hanged.
	2)If enabled the EDFB/DHPM mode, Chip vender suggest to set SATA drive only.
		CLI command: EDFB [sata | off] {cx, cy, ...}
	3)We disabled the function to turn off powersupply module when its fan failed, by default.
	4)Fix device ID 0x3A (12 bays) sometimes will return Host with fan 2 failed status.
		

MFG data : Mfg12g160413.dat, Mfg12gN160413.dat
	command "fdl mfgb" to update

	No new patch.


2016/06/06 Released
FW : sas3xfw160606.fw
  Revision: 03.01.27.51  06/06/16
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
	
	1)Fix ARC8008/1883IX connect 60 bays JBOD issue.

MFG data : Mfg12g160413.dat, Mfg12gN160413.dat
	command "fdl mfgb" to update

	No new patch.


2016/07/19 Released
FW : sas3xfw160719.fw
  Revision: 03.01.28.55  07/19/16
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
	
	1)Fix some LCM issues.
	
MFG data : Mfg12g160413.dat, Mfg12gN160413.dat
	command "fdl mfgb" to update

	No new patch.


2016/08/19 Released
FW : sas3xfw160619.fw
  Revision: 03.01.29.58  08/19/16
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update
	
	1)Support New device ID 0x54, 12 bays, RAID Tower System
	2)Set Chip Hi-limit temperature to 90'C as default for subsystem expander.
	3)Update ARC8018 LED issue for Avago RAID SAS adapters.
	4)Set all the PHY with the same default group number value.
	
MFG data : Mfg12g160801.dat Mfg12gN160801.dat
	command "fdl mfgb" to update
	
	1)Support New device ID 0x54, 12 bays, RAID Tower System


2017/01/23 Released
FW : sas3xfw170123.fw
  Revision: 03.01.30.5F  01/23/17
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update

	1)Rewrite the rule for device ID 0x3, 0x7
		Customer want to use Expander PCB Ver.B with backplane ARC8008 Ver A/B.
	2)rewrite the code for driven strength command.
	3)support ARC8052-T3 subsystem ID 0x54.
	4)fix I2C read active cable eeprom.


MFG data : Mfg12g170123.dat Mfg12gN170123.dat
	command "fdl mfgb" to update
	
	1)Rewrite device ID 0X3, 0X7 data file, R01
		Customer want to use Expander PCB Ver.B with backplane ARC8008 Ver A/B.
	2)Support device ID 0x3,0x7 PCB Ver.B support ARC-8008 PCB ver A
		03 			Rev. 0x05
		07 			Rev. 0x05
	3)Update device ID 0x54, Rev 04.
		54 			Rev. 0x04


2017/04/26 Released
FW : sas3xfw170426.fw
  Revision: 03.01.31.60  04/26/17
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update

	1)Fix the ARC8018 24 bays products has the issue that slot18 may report unnormal temperature.
	2)ARC8050T3 Device ID 0x54, set EDFB disabled by default. 
	

2017/09/15 Released
FW : sas3xfw170915.fw
  Revision: 03.01.32.62  09/15/17
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update

	1)Set Cable Managemnet as enabled by default, if H/W supported.
	2)when set ARC8028 Fan slot DIP switch as not detect, the CLI still report the Fan slot is OK.
	
	
2017/09/21  Released
MFG data : Mfg12g170921.dat Mfg12gN170921.dat
	command "fdl mfgb" to update
	
	1)Fix ARC8028-32 device ID 0X47, conector phy map.
		54 			Rev. 0x07


2017/11/03 Released
FW : sas3xfw171103.fw
  Revision: 03.01.33.63  11/03/17
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update

	1)Fixed some optical cables connect issue.
	

2017/12/08 Released
FW : sas3xfw171208.fw
  Revision: 03.01.34.65  12/08/17
  Firmware Family: 0  OemFamily: 0
  command "fdl code" to update

	1)Fixed ARC8008 external connector issue.


2018/05/25 Released
FW : sas3xfw180525.fw
	Revision: 03.01.35.67  05/25/18
	Firmware Family: 0  OemFamily: 0
	command "fdl code" to update

	1)Modify LCD some shown strings.


2018/06/07 Released
FW : sas3xfw180607.fw
	Revision: 03.01.36.68  06/07/18
	Firmware Family: 0  OemFamily: 0
	command "fdl code" to update

	1)Fix LCD shown wrong model strings.	


2018/07/18 Released
FW : sas3xfw180718.fw
	Revision: 03.01.37.69  07/18/18
	Firmware Family: 0  OemFamily: 0
	command "fdl code" to update

	1)Fix Windows server tools sometimes will get unnormal status at initial stage.